{"id":2590,"date":"2026-05-13T02:30:00","date_gmt":"2026-05-13T02:30:00","guid":{"rendered":"https:\/\/www.huanhaizhongke.com\/galvanized-coil-storage\/"},"modified":"2026-05-13T02:30:00","modified_gmt":"2026-05-13T02:30:00","slug":"galvanized-coil-storage","status":"publish","type":"post","link":"https:\/\/www.huanhaizhongke.com\/vi\/galvanized-coil-storage\/","title":{"rendered":"L\u01b0u tr\u1eef cu\u1ed9n m\u1ea1 k\u1ebdm: Ng\u0103n ng\u1eeba h\u01b0 h\u1ecfng \u0111\u1ed9 \u1ea9m"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h4>M\u1ee5c l\u1ee5c<\/h4><nav><ul><li><a href=\"#why-quality-requirements-matter\">T\u1ea1i sao y\u00eau c\u1ea7u ch\u1ea5t l\u01b0\u1ee3ng l\u1ea1i quan tr\u1ecdng<\/a><\/li><li><a href=\"#define-acceptance-criteria\">X\u00e1c \u0111\u1ecbnh ti\u00eau ch\u00ed ch\u1ea5p nh\u1eadn<\/a><\/li><li><a href=\"#common-nonconformities\">S\u1ef1 kh\u00f4ng ph\u00f9 h\u1ee3p ph\u1ed5 bi\u1ebfn<\/a><\/li><li><a href=\"#inspection-plan\">K\u1ebf ho\u1ea1ch ki\u1ec3m tra<\/a><\/li><li><a href=\"#storage-and-transport\">L\u01b0u tr\u1eef v\u00e0 v\u1eadn chuy\u1ec3n<\/a><\/li><li><a href=\"#claims-and-traceability\">Khi\u1ebfu n\u1ea1i v\u00e0 Truy xu\u1ea5t ngu\u1ed3n g\u1ed1c<\/a><\/li><li><a href=\"#quality-comparison-table\">B\u1ea3ng So s\u00e1nh Ch\u1ea5t l\u01b0\u1ee3ng<\/a><\/li><li><a href=\"#receiving-checklist\">Nh\u1eadn Checklist<\/a><\/li><li><a href=\"#frequently-asked-questions\">Nh\u1eefng c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/a><\/li><li><a href=\"#request-a-quality-review\">Y\u00eau c\u1ea7u \u0111\u00e1nh gi\u00e1 ch\u1ea5t l\u01b0\u1ee3ng<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">galvanized coil storage affects more than the line item on a purchase order. It influences whether material fits the drawing, runs through the intended process, passes receiving inspection, and performs in service. Storage planning must control condensation, trapped moisture, damaged wrap, floor contact, temperature changes, and time before processing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This galvanized coil storage guide is written for industrial buyers, engineers, quality teams, and fabricators. It concentrates on measurable requirements and practical purchasing decisions, without assuming that one grade, tolerance, finish, or test plan is correct for every project.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-26.jpg\" alt=\"galvanized coil storage for industrial procurement and fabrication\" class=\"wp-image-970\" srcset=\"https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-26.jpg 800w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-26-300x225.jpg 300w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-26-768x576.jpg 768w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-26-600x450.jpg 600w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-quality-requirements-matter\">T\u1ea1i sao y\u00eau c\u1ea7u ch\u1ea5t l\u01b0\u1ee3ng l\u1ea1i quan tr\u1ecdng<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A galvanized coil storage inquiry should begin with the finished component and its operating conditions. Typical uses for galvanized steel sheet and coil include roofing components, wall panels, ducts, cabinets, frames, appliances, agricultural equipment, and outdoor fabrications. The buyer should identify the load, environment, expected life, joining method, appearance requirement, and any regulatory or project specification that controls the work.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">galvanized coil storage becomes easier to specify when procurement receives input from design, production, and quality before quotations are requested. Coils moved from cold transport into a warm humid building can collect condensation even when rain never reaches the package. This review prevents a technically valid material from arriving in a form that creates avoidable cutting, forming, welding, installation, or inspection work.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"define-acceptance-criteria\">X\u00e1c \u0111\u1ecbnh ti\u00eau ch\u00ed ch\u1ea5p nh\u1eadn<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The material baseline for galvanized coil storage should state base steel grade, coating designation, thickness, width, surface treatment, passivation or oiling, appearance, and forming route. A familiar trade name is not a complete specification. The purchase order should identify the governing standard and edition required by the project, because requirements can differ by product form, thickness, grade, temper, and delivery condition.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For galvanized coil storage, buyers should compare certificate wording with the drawing and inquiry rather than relying on visual appearance. A useful independent industry reference is the <a href=\"https:\/\/galvanizeit.org\/\" target=\"_blank\" rel=\"noreferrer noopener\">Hi\u1ec7p h\u1ed9i m\u1ea1 k\u1ebdm M\u1ef9<\/a>. nghi\u1ec7m thu d\u1ef1 \u00e1n v\u1eabn ph\u1ea3i tu\u00e2n theo c\u00e1c v\u0103n b\u1ea3n h\u1ee3p \u0111\u1ed3ng \u0111\u00e3 n\u00eau.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-nonconformities\">S\u1ef1 kh\u00f4ng ph\u00f9 h\u1ee3p ph\u1ed5 bi\u1ebfn<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dimensions for galvanized coil storage need nominal values and accepted variation. Depending on the product, this may include thickness or wall, width, length, diameter, straightness, flatness, ovality, camber, edge condition, coil dimensions, or profile geometry. Warehouse instructions should define inspection timing, dry storage location, drainage, allowable stacking, and the response to wet packaging.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do not request a tighter galvanized coil storage tolerance simply because a smaller number appears more precise. Tolerance should protect fit, forming, sealing, machining allowance, line stability, and final performance. Unnecessary restrictions can reduce sourcing flexibility without improving the part.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"inspection-plan\">K\u1ebf ho\u1ea1ch ki\u1ec3m tra<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The production plan for galvanized coil storage should name every important downstream operation: slitting, leveling, punching, bending, roll forming, joining, painting, and cut-to-length processing. Material condition, directionality, residual stress, edge quality, surface cleanliness, and dimensional variation can affect these processes in different ways.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">galvanized coil storage should be evaluated with the actual equipment and tooling limits in mind. Removing wet wrap, separating affected material, drying surfaces, and documenting condition promptly can limit uncertainty during a claim. When geometry or acceptance is demanding, a representative sample or first-article run is more useful than an unsupported promise that the material is generally suitable.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-25.jpg\" alt=\"galvanized coil storage surface and product form for quality review\" class=\"wp-image-963\" srcset=\"https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-25.jpg 800w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-25-300x225.jpg 300w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-25-768x576.jpg 768w, https:\/\/www.huanhaizhongke.com\/wp-content\/uploads\/2025\/01\/6-25-600x450.jpg 600w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"storage-and-transport\">L\u01b0u tr\u1eef v\u00e0 v\u1eadn chuy\u1ec3n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Surface requirements for galvanized coil storage should be tied to function. Relevant conditions may include zinc coverage, white-rust risk, scratches, bare spots, handling marks, storage stain, and compatibility with painting or bonding. A broad note such as clean surface or good finish is difficult to inspect consistently; visible zones and functional contact areas should have objective acceptance language.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Handling and storage can change galvanized coil storage after production. dry wrapping, edge guards, moisture control, ventilated storage planning, and labels that identify coating and dimensions Receiving teams should photograph wet, torn, crushed, or shifted packaging before material is moved, because later handling can obscure the original condition.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"claims-and-traceability\">Khi\u1ebfu n\u1ea1i v\u00e0 Truy xu\u1ea5t ngu\u1ed3n g\u1ed1c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A proportionate galvanized coil storage inspection plan normally reviews base-metal thickness where specified, coating requirement, width, flatness, edge condition, surface appearance, and certificate traceability. The sampling frequency, instruments, measurement locations, and acceptance limits should be agreed before shipment when the order is critical.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Documentation for galvanized coil storage may include material certificate, coating evidence, dimensional report, packing list, and any project-specific compliance records. Look for white storage stain, dark marks, water tracks, wet cores, damaged edge protection, and moisture beneath otherwise intact wrapping. Records should connect the inspected material to its labels or traceability references so that a finding can be isolated without placing unrelated material on hold.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quality-comparison-table\">B\u1ea3ng So s\u00e1nh Ch\u1ea5t l\u01b0\u1ee3ng<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The correct galvanized coil storage requirement depends on what the buyer is trying to protect. The comparison below turns common purchasing priorities into practical specification actions.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u01afu ti\u00ean ng\u01b0\u1eddi mua<\/th><th>R\u1ee7i ro n\u1ebfu kh\u00f4ng x\u00e1c \u0111\u1ecbnh<\/th><th>H\u00e0nh \u0111\u1ed9ng \u0111\u1eb7t h\u00e0ng h\u1eefu \u00edch<\/th><\/tr><\/thead><tbody><tr><td>K\u00edch th\u01b0\u1edbc ph\u00f9 h\u1ee3p<\/td><td>L\u00e0m l\u1ea1i, l\u1eafp r\u00e1p k\u00e9m ho\u1eb7c x\u1eed l\u00fd kh\u00f4ng \u1ed5n \u0111\u1ecbnh<\/td><td>K\u00edch th\u01b0\u1edbc danh ngh\u0129a tr\u1ea1ng th\u00e1i, dung sai v\u00e0 ph\u01b0\u01a1ng ph\u00e1p \u0111o<\/td><\/tr><tr><td>Ch\u1ebf t\u1ea1o<\/td><td>Cracking, bi\u1ebfn d\u1ea1ng, c\u00e1c v\u1ea5n \u0111\u1ec1 v\u1ec1 d\u1ee5ng c\u1ee5 ho\u1eb7c n\u1ed1i k\u00e9m<\/td><td>\u0110\u1eb7t t\u00ean cho qu\u00e1 tr\u00ecnh, \u0111i\u1ec1u ki\u1ec7n v\u1eadt li\u1ec7u v\u00e0 h\u00ecnh h\u1ecdc quan tr\u1ecdng<\/td><\/tr><tr><td>Hi\u1ec7u su\u1ea5t b\u1ec1 m\u1eb7t<\/td><td>C\u00e1c v\u1ea5n \u0111\u1ec1 v\u1ec1 l\u1edbp ph\u1ee7, li\u00ean k\u1ebft, \u0103n m\u00f2n ho\u1eb7c b\u1ec1 ngo\u00e0i<\/td><td>X\u00e1c \u0111\u1ecbnh c\u00e1c v\u00f9ng ho\u00e0n thi\u1ec7n, b\u1ea3o v\u1ec7 v\u00e0 ch\u1ea5p nh\u1eadn c\u00f3 th\u1ec3 nh\u00ecn th\u1ea5y<\/td><\/tr><tr><td>Kh\u1ea3 n\u0103ng truy xu\u1ea5t ngu\u1ed3n g\u1ed1c<\/td><td>Tuy\u00ean b\u1ed1 ch\u1eadm v\u00e0 danh t\u00ednh v\u1eadt ch\u1ea5t kh\u00f4ng ch\u1eafc ch\u1eafn<\/td><td>Y\u00eau c\u1ea7u gi\u1ea5y ch\u1ee9ng nh\u1eadn, nh\u00e3n m\u00e1c, h\u1ed3 s\u01a1 ki\u1ec3m tra li\u00ean k\u1ebft l\u00f4 h\u00e0ng<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">For galvanized coil storage, the strongest specification is not the longest one. It is the specification that links each requirement to a drawing feature, process limit, service condition, or receiving check. Requirements that cannot be measured or connected to use should be clarified before the order is placed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"receiving-checklist\">Nh\u1eadn Checklist<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A complete galvanized coil storage request should give suppliers the same technical basis. Buyers can review <a href=\"https:\/\/www.huanhaizhongke.com\/vi\/san-pham\/galvanized-sheet\/\">th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt s\u1ea3n ph\u1ea9m t\u1ea5m m\u1ea1 k\u1ebdm<\/a> v\u00e0 nh\u1eefng li\u00ean quan <a href=\"https:\/\/www.huanhaizhongke.com\/vi\/galvanized-steel-coil\/\">th\u00e9p cu\u1ed9n m\u1ea1 k\u1ebdm \u0111\u1eb7c \u0111i\u1ec3m k\u1ef9 thu\u1eadt h\u01b0\u1edbng d\u1eabn<\/a> tr\u01b0\u1edbc khi ho\u00e0n t\u1ea5t cu\u1ed9c \u0111i\u1ec1u tra.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Identify the application and governing standard for galvanized coil storage.<\/li><li>C\u1ea5p ti\u1ec3u bang, t\u00ecnh tr\u1ea1ng ho\u1eb7c t\u00ednh kh\u00ed v\u00e0 t\u1ea5t c\u1ea3 c\u00e1c k\u00edch th\u01b0\u1edbc danh ngh\u0129a.<\/li><li>X\u00e1c \u0111\u1ecbnh dung sai, \u0111i\u1ec1u ki\u1ec7n c\u1ea1nh ho\u1eb7c cu\u1ed1i v\u00e0 c\u00e1c v\u00f9ng b\u1ec1 m\u1eb7t quan tr\u1ecdng.<\/li><li>M\u00f4 t\u1ea3 c\u1eaft, t\u1ea1o h\u00ecnh, gia c\u00f4ng, h\u00e0n, ph\u1ee7, ho\u1eb7c n\u1ed1i.<\/li><li>Danh s\u00e1ch c\u00e1c y\u00eau c\u1ea7u ki\u1ec3m tra, ch\u1ee9ng nh\u1eadn, truy xu\u1ea5t ngu\u1ed3n g\u1ed1c, ghi nh\u00e3n v\u00e0 \u0111\u00f3ng g\u00f3i.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Before approving galvanized coil storage, procurement should confirm that the quotation has no silent substitutions or vague phrases such as standard quality where the project needs a named condition. Technical exceptions should be written and resolved before production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Nh\u1eefng c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-galvanized-coil-storage-specification\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What should a galvanized coil storage specification include?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>N\u00f3 ph\u1ea3i x\u00e1c \u0111\u1ecbnh ti\u00eau chu\u1ea9n, c\u1ea5p \u0111\u1ed9 ho\u1eb7c \u0111i\u1ec1u ki\u1ec7n qu\u1ea3n l\u00fd, k\u00edch th\u01b0\u1edbc, dung sai, b\u1ec1 m\u1eb7t, l\u1ed9 tr\u00ecnh x\u1eed l\u00fd, t\u00e0i li\u1ec7u ki\u1ec3m tra, truy xu\u1ea5t ngu\u1ed3n g\u1ed1c v\u00e0 bao b\u00ec c\u1ea7n thi\u1ebft cho \u1ee9ng d\u1ee5ng.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-galvanized-coil-storage-inspection\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Ng\u01b0\u1eddi mua n\u00ean ki\u1ec3m tra nh\u01b0 th\u1ebf n\u00e0o <\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Ph\u00f9 h\u1ee3p v\u1edbi gi\u1ea5y ch\u1ee9ng nh\u1eadn v\u00e0 nh\u00e3n tr\u01b0\u1edbc, sau \u0111\u00f3 ki\u1ec3m tra k\u00edch th\u01b0\u1edbc, h\u00ecnh d\u1ea1ng s\u1ea3n ph\u1ea9m, b\u1ec1 m\u1eb7t, c\u1ea1nh ho\u1eb7c k\u1ebft th\u00fac, v\u00e0 b\u1ea5t k\u1ef3 th\u1eed nghi\u1ec7m c\u00f3 t\u00ean trong \u0111\u01a1n \u0111\u1eb7t h\u00e0ng b\u1eb1ng c\u00e1ch s\u1eed d\u1ee5ng m\u1ed9t k\u1ebf ho\u1ea1ch l\u1ea5y m\u1eabu t\u00e0i li\u1ec7u.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-galvanized-coil-storage-tolerance\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Khi n\u00e0o th\u00ec s\u1ef1 khoan dung ch\u1eb7t ch\u1ebd h\u01a1n l\u00e0 h\u1ee3p l\u00fd<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Dung sai ch\u1eb7t ch\u1ebd h\u01a1n l\u00e0 h\u1ee3p l\u00fd khi s\u1ef1 thay \u0111\u1ed5i ti\u00eau chu\u1ea9n c\u00f3 th\u1ec3 \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn \u0111\u1ed9 v\u1eeba v\u1eb7n, \u0111\u1ed9 k\u00edn, ph\u1ee5 c\u1ea5p gia c\u00f4ng, h\u00ecnh d\u1ea1ng, \u0111\u1ed9 \u1ed5n \u0111\u1ecbnh c\u1ee7a \u0111\u01b0\u1eddng, h\u00ecnh th\u1ee9c b\u00ean ngo\u00e0i ho\u1eb7c y\u00eau c\u1ea7u c\u00f3 th\u1ec3 \u0111o l\u01b0\u1eddng kh\u00e1c c\u1ee7a b\u1ed9 ph\u1eadn ho\u00e0n thi\u1ec7n.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-galvanized-coil-storage-sample\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Ng\u01b0\u1eddi mua c\u00f3 n\u00ean y\u00eau c\u1ea7u m\u1ed9t m\u1eabu tr\u01b0\u1edbc khi \u0111\u1eb7t h\u00e0ng s\u1ed1 l\u01b0\u1ee3ng l\u1edbn?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>M\u1ed9t th\u1eed nghi\u1ec7m m\u1eabu ho\u1eb7c b\u00e0i vi\u1ebft \u0111\u1ea7u ti\u00ean l\u00e0 h\u1ee3p l\u00fd khi v\u1eadt li\u1ec7u s\u1ebd ph\u1ea3i \u0111\u1ed1i m\u1eb7t v\u1edbi c\u00e1c y\u00eau c\u1ea7u kh\u1eaft khe v\u1ec1 t\u1ea1o h\u00ecnh, th\u1ea9m m\u1ef9, n\u1ed1i, ph\u1ee7 ho\u1eb7c x\u1eed l\u00fd ch\u00ednh x\u00e1c m\u00e0 kh\u00f4ng th\u1ec3 x\u00e1c nh\u1eadn ch\u1ec9 t\u1eeb t\u00e0i li\u1ec7u.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-galvanized-coil-storage-documents\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Nh\u1eefng t\u00e0i li\u1ec7u n\u00e0o l\u00e0 quan tr\u1ecdng nh\u1ea5t?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>The required documents depend on the project, but galvanized coil storage commonly needs a material certificate, traceability, dimensional or test records where specified, and a packing list linked to the shipment.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"request-a-quality-review\">Y\u00eau c\u1ea7u \u0111\u00e1nh gi\u00e1 ch\u1ea5t l\u01b0\u1ee3ng<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Send Huanhai Zhongke the drawing, standard, grade, dimensions, process route, service environment, and inspection needs for a galvanized coil storage specification review before requesting a quotation.<\/p>","protected":false},"excerpt":{"rendered":"<p>galvanized coil storage affects more than the line item on a purchase order. It influences whether material fits the drawing, runs through the intended process, passes receiving inspection, and performs in service. Storage planning must control condensation, trapped moisture, damaged wrap, floor contact, temperature changes, and time before processing. This galvanized coil storage guide is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":970,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[30],"tags":[],"class_list":["post-2590","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/posts\/2590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/comments?post=2590"}],"version-history":[{"count":0,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/posts\/2590\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/media\/970"}],"wp:attachment":[{"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/media?parent=2590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/categories?post=2590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huanhaizhongke.com\/vi\/wp-json\/wp\/v2\/tags?post=2590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}